The CSB issues safety recommendations to prevent the recurrence or reduce the likelihood or consequences of similar incidents or hazards in the future. Recommendations are issued to a variety of parties, including government entities, safety organizations, trade unions, trade associations, corporations, emergency response organizations, educational institutions, and public interest groups. Recommendations are published in CSB reports and are closed only by vote of the Board. The CSB tracks all recommendations and communicates regularly with recommendations recipients to ensure that the recommended corrective actions are implemented.

For more information, see Frequently Asked Questions about CSB recommendations.


Quick Search

 
Recommendations Status:
 
 
Expand All

Recommendations

Carbide Industries Fire and Explosion (3 Recommendations)
Carbide Industries (2 Recommendations)
Open: 0% | Closed: 100%

Final Report Released On: February 07, 2013

2011-5-I-KY-2

Modify the design and procedures for the electric arc furnace and related structures including the control room to comply with the NFPA standard developed per R1 of this case study.  


Status: Closed - No Longer Applicable
Closed - No Longer Applicable (C - NLA) - Due to subsequent events, the recommendation action no longer applies (e.g., the facility was destroyed or the company went out of business).
 

PDF Document Recommendations Status Change Summary

2011-5-I-KY-3

Implement a mechanical integrity program for the electric arc furnace and cover, including preventive maintenance based on periodic inspections, and timely replacement of the furnace cover. At a minimum, the program should include factors such as leak detection and repair and refractory lining wear.


Status: Closed - Acceptable Action
Closed - Acceptable Action (C - AA) - The recipient has completed action on the recommendation. The action taken meets the objectives envisioned by the Board.
 

PDF Document Recommendation Status Change Summary

National Fire Protection Association (NFPA) (1 Recommendations)
Open: 0% | Closed: 100%

Final Report Released On: February 07, 2013

2011-5-I-KY-1

Establish a committee to evaluate and develop a standard that defines the safety requirements for electric arc furnaces operated with flammable materials and low oxygen atmospheres. At a minimum, establish requirements that electric arc furnaces containing flammables have: • Adequate safety instrumentation and controls to prevent explosions and overpressure events; • Mechanical integrity and inspection programs; • A documented siting analysis to ensure that control rooms and other occupied areas are adequately protected.  


Status: Closed - Reconsidered/Superseded
Closed - Reconsidered/Superseded (C - R/S) - Recipient rejects the recommendation and also supports the rejection with a rationale with which the Board concurs. This designation may apply when later facts indicate that the concerns expressed in the recommendation were actually addressed prior to the incident, or when a recommendation is superseded by a new, more appropriate recommendation.
 

PDF Document Recommendations Status Change Summary